FTA-T-14 HONEYWELL Input/Output (I/O) module

The HONEYWELL FTA T-14 is a general-purpose input/output(I/O)module commonly used in Honeywell fault-tolerant control systems.

Number of input channels:The number and type of input signals that the module can receive(such as digital input,analog input,etc.).

Number of output channels:The number and type of output signals that the module can provide(such as digital output,analog output,etc.).

Voltage/current range:The input voltage/current range acceptable to the module,and the output voltage/current size.

Input/output type:Input/output signal type supported by the module,such as digital input/output,analog input/output,thermocouple,RTD,etc.

Response time:How quickly the module responds to changes in the input signal.

Communication interface:Interface type of the module used to communicate with the control system,such as Ethernet,Modbus,etc.

Operating temperature:indicates the temperature range at which the module works normally.

Installation mode:Module installation mode,such as guide rail installation,rack installation,etc.

Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: sales@runshengdcs.com
  • WhatsApp / Wechat:+86 15383419322
  • Phone:+86 15383419322

Description

HONEYWELL FTA T-14 Product information

Product description

The HONEYWELL FTA T-14 is a general-purpose input/output(I/O)module commonly used in Honeywell fault-tolerant control systems.It is designed to receive input signals from field devices(such as sensors,switches,etc.)and provide output signals to field devices(such as valves,relays,motors,etc.)to perform various control operations.

FTA-T-14 HONEYWELL

FTA-T-14 HONEYWELL

Product parameter

Number of input channels:The number and type of input signals that the module can receive(such as digital input,analog input,etc.).

Number of output channels:The number and type of output signals that the module can provide(such as digital output,analog output,etc.).

Voltage/current range:The input voltage/current range acceptable to the module,and the output voltage/current size.

Input/output type:Input/output signal type supported by the module,such as digital input/output,analog input/output,thermocouple,RTD,etc.

Response time:How quickly the module responds to changes in the input signal.

Communication interface:Interface type of the module used to communicate with the control system,such as Ethernet,Modbus,etc.

Operating temperature:indicates the temperature range at which the module works normally.

Installation mode:Module installation mode,such as guide rail installation,rack installation,etc.

Product specification

Interface type:Electrical interface type,such as wiring terminals and connectors.

Protection level:The protection level of the module,such as IP20 and IP67,indicates the protection capability against external environment such as dust and water.

series

The FTA-T-14 is part of Honeywell’s family of universal I/O modules.Honeywell has an extensive product line in industrial automation,including various types of control modules and devices.

trait

Honeywell Universal I/O modules typically have the following characteristics:

Flexibility:Supports a variety of input/output signal types and can be flexibly configured to meet different application requirements.

High reliability:The use of high-quality electronic components and connectors,with high reliability and stability,can operate in harsh industrial environments for a long time.

Fast response:It has a fast response time and can collect input signals and control output signals in time.

Status indicator:Each channel usually has a status indicator to facilitate the user to know the channel status.

Easy to use:Provides a friendly user interface and configuration tools for easy setup and maintenance.

effect

The main functions of the universal I/O module are:

Collect field signals:Receive various input signals from field equipment,such as sensor signals,switch signals,etc.

Control field equipment:According to the instructions of the control system,provide various output signals to the field equipment,such as control valves,relays,motors,etc.

Signal conversion:The signal of the field equipment is converted into a signal that the control system can recognize and process,or the signal of the control system is converted into a signal that the field equipment can accept.

use

General purpose I/O modules are widely used in various industrial automation fields,such as:

Power industry:various control systems for power plants and substations,such as generator control,transmission and distribution control.

Metallurgical industry:Various control systems used in steel plants,such as steelmaking process control,rolling process control,etc.

Petrochemical:used in various control systems in refineries and chemical plants,such as process control and pipeline transportation control.

Manufacturing:Various control systems for automated production lines,such as robot control,material handling control,etc.

FTA-T-14 HONEYWELL

FTA-T-14 HONEYWELL

Application field

The FTA-T-14 is mainly used in industrial areas that require general-purpose I/O functions,such as:

Process control:Used for automatic control of various industrial processes,such as temperature control,pressure control,flow control,etc.

Motion control:Used for motion control of various mechanical equipment,such as servo motor control,stepper motor control,etc.

Safety system:Used for safety related systems such as emergency shutdown system and fire alarm system.